200 Inverted Rib

200 Inverted Rib Wall Panel

The 200 Inverted Rib insulated metal panel is ideal for new and retrofit applications across commercial and industrial market sectors. The 42” cover width allows for simple installation and fast building close in. With insulation thicknesses ranging from 2” – 6”, the 200 Inverted Rib panel provides superior thermal performance.

  • Exterior and Interior faces are available in 26, 24 and 22 gauge
  • Nineteen Kynar finishes standard or custom color matching possible
  • Foamed-in-place manufacturing process produces consistent high quality
  • Panels are offered with optional factory-caulked side joints to save erection labor
  • A variety of interior faces are available to provide a unique, finished appearance
  • GREENGUARD Gold Certified
200 Inverted Rib Wall Panel

Product Information

Profile Exterior: Inverted Rib
Interior: Minor Rib, Shadowline or V-groove
Embossing Exterior: Stucco or non-embossed
Interior: Stucco or non-embossed
Gauge Exterior: 26, 24, 22 ga
Interior: 26, 24, 22 ga
Width 42”
Thickness 2", 2.5", 3", 4", 5", 6"
Length 8' - 53'
Reveal option N/A
Orientation Vertical
Post fabrication N/A
R-value ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Test Procedure Results
Fire FM-4880 Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems
ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
ULC-S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials
ULC-S102 Standard Method of Test for Surface Building Characteristics of Building Materials and Assemblies
ULC-S127 Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Building Materials
UBC26-4 / NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
NFPA 259 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Strength FM-4881 Approval Standard for Class 1 Exterior Wall Systems
ASTM E72 Chamber Method Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°   Thermal Performance at 35°
Thickness U-Factor R-Value Thickness U-Factor R-Value
2 0.07 14.4 2 0.06 16
2.5 0.06 18.0 2.5 0.05 20
3 0.05 21.6 3 0.04 24
4 0.03 28.8 4 0.03 32
5 0.03 36.0 5 0.03 40
6 0.02 43.2 6 0.02 48
Air Infiltration ASTM E283 0.003 CFM/ft² of Panel Area at 6.24 psf
Water Penetration ASTM E331 No Water Penetration at 20.0 psf
Fatigue Subjected to 2 million alternate cycles of 20 PSF positive and
negative wind loading
No metal / foam delamination or metal fatigue
Humidity Sample subjected to 100% relative humidity at 140°F for 1000 hours No evidence of metal primer corrosion
Autoclave Sample placed in an autoclave device and pressurized to 2 PSI
at 212°F for 2½ hours
No evidence of delamination
Skin Delamination   No skin delamination with direct pull off pressure up to 1188 psf

At Kingspan, we understand the unique challenges that design and construction professionals face every day.  To do our part in meeting these demands, Kingspan products are offered with our team’s guidance and technical expertise, followed up after construction is completed with our product warranties:
 

  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 
Contact our sales or customer service departments for information regarding our optional warranty programs.
 

200 Inverted Rib Wall Panel

Download

Text Us